Bare Metal Edge node loses connectivity after upgrading firmware of Intel XXV710 nics
book
Article ID: 317184
calendar_today
Updated On:
Products
VMware NSX
Issue/Introduction
Symptoms:
NIC will be unstable with firmware 20.0.17
NIC will be completely down with firmware 20.5.13
Environment
VMware NSX-T Data Center 3.x
VMware NSX-T Data Center
Cause
DPDK firmware support matrix for X710/XL710/XXV710 has
18.05 6.01
19.11 7.0
NSX 3.1 uses DPDK 18.05, but some driver updates have been backported, so 7.1 does work.
NSX 3.2 will use DPDK 19.11.
Resolution
Customers running Bare Metal Edges in NSX-T 3.1 should not upgrade Intel XXV710 firmware above 19.5.12 (driver 7.1)
Newer firmware will work with later versions of NSX-T.
Workaround:
Downgrade firmware to 19.5.12