VIC OVA install wizard accepts a longer password than the VIC plugin installer allows
book
Article ID: 317022
calendar_today
Updated On:
Products
VMware vSphere ESXi
Issue/Introduction
Symptoms:
VIC plugin install during the VIC Appliance initialization fails with "Validation failed: VIC appliance password is incorrect." when using very long passwords.
You see messages similar to the following in the fileserver logs in the VIC appliance:
Apr 09 15:50:45 vicappliance00.gsslabs.org start_fileserver.sh[1394]: Apr 9 2019 15:50:45.857Z INFO op=1400.14: VIC appliance password length is more than 30. Apr 09 15:50:45 vicappliance00.gsslabs.org start_fileserver.sh[1394]: Apr 9 2019 15:50:45.857Z ERROR op=1400.14: Install failed: VIC appliance password is incorrect.
Note: you can access the fileserver logs on the VIC appliance by running journalctl -u fileserver.service | grep password
Environment
VMware vSphere Integrated Containers 1.5.x
Resolution
Supported password length is 30 characters in versions VIC 1.5.0 - 1.5.2. This issue is resolved in VIC 1.5.3.