VMware Enterprise PKS Bosh director tile displays 'Error connecting to vCenter IP: Net::OpenTimeout', type: IaasConfigurationVerifier
search cancel

VMware Enterprise PKS Bosh director tile displays 'Error connecting to vCenter IP: Net::OpenTimeout', type: IaasConfigurationVerifier

book

Article ID: 316790

calendar_today

Updated On:

Products

VMware Cloud PKS

Issue/Introduction

Symptoms:
  • In OpsMan, after clicking Save in the Bosh Director tile in the vCenter Config section, you see the following error:
'Error connecting to vCenter IP: Net::OpenTimeout', type: IaasConfigurationVerifier


Environment

VMware PKS 1.x

Cause

This issue occurs because the virtual distributed switch that the NSX-T Manager VM management interface is using has MTU set for 1500.

Resolution

To resolve this issue, ensure that the virtual distributed switches that use the NSX-T overlay network are set to MTU of 1600 or higher.