When restarting ESXi management agents on HP ProLiant G5, G6 and G7-series servers running versions of HP Agentless Management Service (AMS) prior to 10.1.0 , you experience these symptoms:
This issue occurs when you use an older HP Customized VMware image to update any HP ProLiant G5, G6 or G7 servers running VMware ESXi 5.0, 5.1 or 5.5. These models cause the HP Agentless Management Service (AMS), Versions 9.5, 9.6 or 10.0 to make continuous restart attempts and potentially fill up syslog with this message:
root: hp-ams-wd: Detected one or more hpHelper process(es) have stopped running. Restarting...Currently, HP AMS is only supported on ProLiant Gen8 (or later) hosts.
To install the latest HP AMS VIB in an existing ESXi installation, follow the instructions in Download and install async drivers in VMware ESXi.
You can find the HP Agentless Management Service (AMS) Offline Bundle for VMware vSphere 5.5, hp-ams-esxi5.5-bundle-10.1.0-12.zip, dated 30 Mar 2015 at * RECOMMENDED * HP Agentless Management Service Offline Bundle for VMware vSphere 5.5.