VSA Notif 10.1.x Versions does not process all traps after Failover on Smarts OI domain
search cancel

VSA Notif 10.1.x Versions does not process all traps after Failover on Smarts OI domain

book

Article ID: 315667

calendar_today

Updated On:

Products

VMware Smart Assurance

Issue/Introduction

Traps that call an ASL file not being received by OI domain after a Failover 

SMARTS Version 10.1.7 Operating on RHEL8 Platform Presently have InCharge-OI, Incharge-OI Trap and Trap exploder operating on the SAM VM in which services are redundant via failover manager.

When simulating a failover by stopping active services, the services indeed failover to the Standby Server.  Traps using any ASL to the newly active OI will not process, unless the failed server processes are restarted

Resolution

Currently a fix has been tested and this will be available in a future patch release for 10.1.7 and 10.1.9