"Frequent PowerOn Reset Unit Attentions are occurring on device naa.##########. This may indicate a storage problem. Affected datastores: <datastore>"[scsiCorrelator] 5062293xxxx05us: [vob.scsi.scsipath.por] Power-on Reset occurred on vmhba37:C0:T1:L200[scsiCorrelator] 130882373xxx5us: [vob.scsi.scsipath.por] Power-on Reset occurred on naa.##############
cpu7:2055)NMP: nmp_ThrottleLogForDevice:2318: Cmd 0x2a (0x41244038d380, 2056) to dev "naa.###################" on path "vmhba1:C0:T1:L0" Failed: H:0xb D:0x0 P:0x0 Possible sense data: 0x0 0x0 0x0. Act:NONE Adapter: vmhba# Tx Frames: 2656285829 Rx Frames: 3558837439 Lip Count: 0 Error Frames: 763 Dumped Frames: 0 Link Failure Count: 0 Loss of Signal Count: 0 PrimSeq Protocol Err Count: 0 Invalid Tx Word Count: 0 Invalid CRC Count: 763 ---> ESXi host shows massive CRC count Input Requests: 0 Output Requests: 0 Control Requests: 0VMware ESXi 7.x
VMware ESXi 8.x
The messages are caused by activity outside of ESXi’s control, only the storage administrator and vendor can isolate the root cause and provide corrective actions.
Note: This issue is likely caused by a hardware or configuration problem within the SAN. Addressing the underlying issue is crucial to ensure the stability and performance of your virtualized environment.