Issue/Introduction

Symptoms:




Syslog Adapter starts but does not send any Syslog notifications into the OI Server

Environment

VMware Smart Assurance - SMARTS

Cause

The --rules parameter specifying the trap_mgr_parse.asl is not at the end of the command as required.

Resolution

Make sure the syntax of the of the command used to start up the trap adapter ends with the asl file name.

sm_adapter
--name=SYSLOG-INCHARGE-OI
--rserver=INCHARGE-OI
--tail=/var/log/syslog
--model=sm_system
--model=sm_actions
--output
icoi-syslog/syslog_mgr.asl