/var/log/vmkernel
(ESX) or /var/log/messages
(ESXi) log file, you see an entry similar to:IPMI message handler: BMC returned incorrect response, expected netfn A cmd XX, got netfn B cmd YY
This message indicates that the response received from the Baseboard Management Controller (BMC) does not match the request that was issued.
This issue may occur if the CIM and IPMI components in ESXi/ESX 4.x lose synchronization with the hardware BMC, for example, when the BMC firmware is flashed or reset. The host may lose synchronization with the hardware BMC when another software or hardware client makes a conflicting request of the BMC or due to a hardware or software defect that leads to erroneous requests and/or responses.
Note: For related information, see IPMI logs in ESX/ESXi 4.x consume excessive disk space after a BMC reset or firmware update (2000089).
If these messages are reported occasionally in the log files, you can safely ignore them. However, if the log file contains a log spew of this message, they may be symptomatic of an underlying issue. In this case, try one of the options: