[VMC on AWS] HCX Reverse vMotion fails with message "Hosts were not able to connect over the vmotion network"
book
Article ID: 314126
calendar_today
Updated On:
Products
VMware Cloud on AWS
Issue/Introduction
Reverse vMotion(from VMC to on-prem) fails with message "Hosts were not able to connect over the vMotion network"
Service Mesh diagnostics failed probes confirm host reachability issues.
HCX-WAN-IX is unable to reach the Service_HostSystem on the ports 8000.
Environment
Applicable only for VMC environments.
Cause
The 'extraConfig.sddcaas.management.ip' parameter is missing from the ESX host net-dvs property.
Resolution
If you suspect that you are encountering the issue described in this KB article, please collect the following details and provide them when opening a Service Request (SR) with the Broadcom VMC team.