The purpose of Hardware Health Tab is to report only IPMI Sensors that have actual health state.
This displays IPMI Sensor status of the hardware running on ESXi and provide current statistics such as Fan RPM, CPU temperature, power supply voltage and battery status.
This data is provided by PC hardware IPMI (Baseboard Management Controller) using the
/dev/ipmi0 driver which supplies Sensor Data Record (SDR) and current readings, System Event Log (SEL) entries and Field Replaceable Unit (FRU)part numbers.
This tab immediately displays an operator on the sensors which have failed and to make it evident which sensors are currently reporting normal health state but had failed recently.
Symptoms:
- The Hardware Health tab from the vCenter Server 6.5 User is not placing IPMI Sensors into the same groups as prior vCenter Server releases.
- Some groups (such as BMC, PCI) are not populated.