On VMware SD-WAN Edge 620, 640, 680, 840, 2000, and 3X00 models, configuring a LAN-side port as switched can result in a lower maximum throughput. The lower throughput is the result of DPDK network interface optimizations being unavailable on a switched port versus a routed port. It is recommended that a default routed port is not configured as a switched port for this reason. It is also recommended to configure the default switched ports to routed ports when maximum throughput is needed.
The configuration change can be done at the Edge or Profile level.
This is done by going to
Configure > Profile/Edge, select the
Device tab and scroll down to
Interface Settings. Once there, select
Edit for the Interface to be changed and then modify "Capability" as needed. Additionally, following changes are needed before clicking on the
Update GE# to confirm the change.
- Uncheck WAN Overlay, as the port will be used for LAN communication.
- Check 'Advertise' to ensure that the subnet is distributed.
- Uncheck NAT Direct traffic.
![](https://api-broadcomcms-software.wolkenservicedesk.com/attachment/get_attachment_content?uniqueFileId=1512282434071)
If a static route is configured to use this interface, please configure the Interface setting under
Configure > Device > Static Route Settings.
![](https://api-broadcomcms-software.wolkenservicedesk.com/attachment/get_attachment_content?uniqueFileId=1512279885561)
If the Edge has overridden the Profile interface configuration, please make all changes at the Edge level.
Once the configuration changes are complete and have been applied, the final step is to reboot the Edge in a prearranged maintenance window. The reboot is required to enable DPDK optimizations for the routed port. Until the Edge is rebooted the customer would observe no change in maximum throughput performance for that port.