Rebooting the storage node on the target side may affect VM IOs using the vVOL datastore.
book
Article ID: 311908
calendar_today
Updated On:
Products
VMware vSphere ESXi
Issue/Introduction
Symptoms: VM IOs backed by vVOL datastore could be impacted when a storage node reboot is performed on the target side.
Environment
VMware vSphere ESXi 8.0.1
Cause
When a storage node reboot is performed on the storage target side, the IOs will be failed by the target, these IOs need to be retried by ESXi on a different path. However, there was a bug in ESXi that prevented the retry of these IOs, causing them to fail and affecting the VM IOs.
Resolution
"An issue related to the path failover mechanism and subsequent I/O retries for vVol devices was identified. The relevant code path has been rectified to ensure proper I/O retry behavior. This issue has been addressed in ESX 8.0.1.0 Patch 02."