Virtual machine experiences temporary packet loss after vMotion of an NSX-V Edge
book
Article ID: 309612
calendar_today
Updated On:
Products
VMware NSX
VMware vSphere ESXi
Issue/Introduction
Symptoms:
- After vMotion of an NSX-V Edge services gateway, the traffic flow is interrupted for up to 30 seconds.
- Packet captures confirm that a gratuitous ARP is sent to the physical switch.
- The physical switch is an HP switch, and the switch's ARP tables are not updated immediately after the GARP is sent.
Environment
VMware NSX for vSphere 6.0.x
VMware NSX for vSphere 6.1.x
VMware vSphere ESXi 5.5
Cause
This issue is a known issue with certain HP switches.
Resolution
To resolve this issue, apply the
mac-address mac-move fast-update global switch configuration setting.
Note:
- Use mac-address mac-move fast-update to enable ARP fast update for MAC move.
- Use undo mac-address mac-move fast-update to restore the default.
Feedback