Troubleshooting ESX and ESXi connectivity to iSCSI arrays using hardware initiators
search cancel

Troubleshooting ESX and ESXi connectivity to iSCSI arrays using hardware initiators

book

Article ID: 308930

calendar_today

Updated On:

Products

VMware vSphere ESXi

Issue/Introduction

This article guides you through the most common steps to identify a connectivity problem from an ESX or ESXi to an iSCSI shared storage device when using a hardware initiator.

Symptoms:
  • One ESX or ESXi host cannot see any targets from all storage arrays
  • The array does not report the HBA of the ESX or ESXi as being logged in


Environment

VMware vSphere ESXi 5.0
VMware vSphere ESXi 5.5
VMware ESXi 4.1.x Embedded
VMware ESX Server 3.0.x
VMware ESXi 3.5.x Embedded
VMware ESX Server 3.5.x
VMware ESXi 3.5.x Installable
VMware vSphere ESXi 5.1
VMware ESXi 4.0.x Installable
VMware ESXi 4.1.x Installable
VMware ESX 4.0.x
VMware ESX 4.1.x
VMware ESXi 4.0.x Embedded

Resolution

Validate that each troubleshooting step below is true for your environment. Each step provides instructions or a link to a document, in order to eliminate possible causes and take corrective action as necessary. The steps are ordered in the most appropriate sequence to isolate the issue and identify the proper resolution. Do not skip a step.

To troubleshoot a connectivity problem from an ESX or ESXi to an iSCSI shared storage device when using a hardware initiator:

  1. Verify that the ESX or ESXi cannot see any targets on shared storage. For more information, see Obtaining LUN pathing information for ESX or ESXi hosts (1003973).

  2. Verify that a rescan does not restore visibility to the targets. For more information, see Performing a rescan of the storage on an ESX/ESXi host (1003988).

  3. Verify that the Host Bus Adapter (HBA) is listed on the I/O Compatibility Guide found on the Confirming ESX/ESXi host hardware (System, Storage, and I/O) compatibility (1003916).

  4. Verify that the storage array is listed in the VMware Hardware Compatibility Guide and that the firmware is at the required level. Consult your storage array vendor for details regarding the latest supported firmware version.

  5. Verify that the initiator is registered on the array, and that the storage array is configured correctly. Partner with the hardware vendor to ensure that the array is properly configured. For more information, see the iSCSI SAN Configuration Guide.

  6. Verify that the physical hardware is functioning correctly. You may have to contact your hardware vendor for information about verifying your hardware functions correctly.

Note: If your problem still exists after trying the steps in this article, please:



Additional Information

Confirming ESX/ESXi host hardware (System, Storage, and I/O) compatibility
Obtaining LUN pathing information for ESX or ESXi hosts
Performing a rescan of the storage on an ESX/ESXi host
ESX, ESXiとハードウェアイニシエータをつかったiSCSI アレイ接続に関するトラブルシューティング