Symptoms:
When installing the ESXi host on a Cisco UCS C220 server, you experience these symptoms:
  • The ESXi host fails to recognize the RAID volume.
  • Individual disks on the host get listed.


Cause

This issue occurs when the embedded RAID controller is not supported by the ESXi host. As a result, the installation fails to recognize the RAID volume that you have created with this controller.

Resolution

To resolve this issue, use a PCIe or Mezzanine base controller for the installation. This is a list of supported Mezzanine and PCI RAID controllers:
ControllerStyleMaximum drivesSCPMRAID levelsRequired cables
CISCO UCS RAID SAS 2008M-8i: PID UCSC-RAID-MZ-C220Mezzanine4 Internal No0, 1, 1E, 104 drives: 1 mini-SAS (UCSC-CABLE3)
CISCO UCS RAID SAS 2008M-8i: PID UCSC-RAID-11-C220 (Includes RAID 5 and 50)Mezzanine4 Internal No0, 1, 1E, 5, 10, 504 drives: 1 mini-SAS (UCSC-CABLE3)
LSI MegaRAID SAS 9266CV-8i:
The Cache memory of this controller is ECC-protected.
PCIe4 Internal SCPM0, 1, 5, 6, 10, 50, 604 drives: 1 mini-SAS (UCSC-CABLE3)
LSI MegaRAID SAS 9271-8i:
The cache memory of this controller is ECC-protected.
PCIe8 Internal No0, 1, 5, 6, 10, 50, 60
4 drives: 1 mini-SAS (UCSC-CABLE1)
8 drives: 2 mini-SAS (UCSC-CABLE1)
LSI MegaRAID SAS 9271CV-8i:
The cache memory of this controller is ECC-protected.
PCIe8 Internal SCPM0, 1, 5, 6, 10, 50, 60
4 drives: 1 mini-SAS (UCSC-CABLE1)
8 drives: 2 mini-SAS (UCSC-CABLE1)
LSI MegaRAID SAS 9285CV-8ePCIe8 ExternalSCPM0, 1, 5, 6, 10, 50, 60Not sold by Cisco
LSI MegaRAID SAS 9286CV-8ePCIe8 ExternalSCPM0, 1, 5, 6, 10, 50, 60Not sold by Cisco