List of OIDs does IP Manager uses to discover, monitor and generate alarms for "Power Supply" when a device is instrumented to use CiscoStack where the device certification file has following configuration:
CONT = Cisco-StackEnvironment = CiscoStack
All Supported Smarts releases
Smarts IP uses the following OIDs to discover, monitor and generate alarms for Power Supply on devices instrumented to use Cisco-Stack.
.1.3.6.1.4.1.9.5.1.2.3 (chassisPs1Type).1.3.6.1.4.1.9.5.1.2.6 (chassisPs2Type).1.3.6.1.4.1.9.5.1.2.20 (chassisPs3Type)
If the type returned by the above OIDs is not 2 ("none"), Smarts IP creates the PowerSupply, and the description will contain the type obtained from polling the above OIDs.
1.3.6.1.4.1.9.5.1.2.4 (chassisPs1Status)1.3.6.1.4.1.9.5.1.2.7 (chassisPs2Status)1.3.6.1.4.1.9.5.1.2.21 (chassisPs3Status)
The above OIDs have the following possible status values that determine whether Smarts IP will generate an alarm:
1 : other2 : ok3 : minorFault4 : majorFault