Custom Polling and Threshold (P&T) group
search cancel

Custom Polling and Threshold (P&T) group

book

Article ID: 304120

calendar_today

Updated On:

Products

VMware Smart Assurance

Issue/Introduction

  • Create Custom Polling and Threshold (P&T) group.
  • Change P&T for a device since device needs different threshold value.
  • Device is a member of the wrong Smarts Polling/Threshold Group

Environment

Smarts - 10.1.x/24.3.x

Resolution

Change P&T 

  • Identify if the device is a member of any other group. If it is, make sure the group you want it to be a member of has a higher priority than that group:
    • Go to the Priority Tab for the Polling/Threshold group.
    • Raise the priority level as needed, see screenshot for reference:
    • Run a reconfigure to update members.
  • If a device is not a member of any other group, make sure the matching criteria for the group you create will match on the device in question.

Create custom P&T 

  • Identify where new custom group to be created.
  • Right click and select "New Group", see image:
  • Provide "Name" and "Description" as per your requirement.
  • Select the group and add "Settings" which all is needed as per your requirement, see image:
  • Move this new group to top of "Priorities" since if a device is member of other high priority group, it will not be added in newly created group, see image:


  • Make "Matching Criteria" to match device.
  • Apply the changes.
  • Reconfigure the domain
  • Ensure the device is added as member to newly created group.