Smarts IP: Juniper M40e device CIP card shows "OTHER" status; How does Smarts determine the Card Status on a Juniper M40e device?
book
Article ID: 303776
calendar_today
Updated On:
Products
VMware Smart Assurance
Issue/Introduction
Symptoms:
How does Smarts determine the Card Status on a Juniper M40e device?
A CIP card on a Juniper M40e device is showing as "OTHER" status
Environment
VMware Smart Assurance - SMARTS
Cause
Values of "online" (6) and "standby" (10) will produce "OK" values for the card status of the device. The value of "present" (3) will produce a status of "OTHER". This functionality is by design as a "present" status does not reflect the operational state of the card sufficiently to signify an "OK" status.
Resolution
The card status on a Juniper M40e device is determined from the OID 1.3.6.1.4.1.2636.3.1.15.1.8. This OID indicates the operational status of the submodule. Valid values for this OID include the following: