How are "StateNotNormalCpuVoltage" notifications triggered in Smarts IP for Cisco devices?
What OIDs does Smarts IP poll for Cisco devices that support the "ALTIGA-HARDWARE-STATS-MIB"?




Smarts IP triggers "StateNotNormalCpuVoltage" notifications for Cisco devices that support the "ALTIGA-HARDWARE-STATS-MIB" as follows:
  1. Smarts IP polls the following OIDs:

    OID 1.3.6.1.4.1.3076.2.1.2.22.1.2
    OID 1.3.6.1.4.1.3076.2.1.2.22.1.1
     
  2. These OID values are updated by the device when the CPU voltage is detected out of its configured range. Smarts IP triggers a "stateNotNormalCpuVoltage" notification when both of the following conditions are met for these OIDs:

    OID 1.3.6.1.4.1.3076.2.1.2.22.1.2 (alHardwareCpuVoltageAlarm) = true (1) and

    OID 1.3.6.1.4.1.3076.2.1.2.22.1.1 (alHardwareCpuVoltage) is greater than 0