Smarts Network Configuration Manager (Smarts NCM) ControlDaemon service is in loop during restart of service hence it will not start.
daemon.log:
(main) Exception in Device Services Daemon
java.lang.IllegalArgumentException: Invalid IP Address [null]
server.log:
class com.powerup.common.CMSystemException:Unable to communicate with DeviceManagementService (please check if ControlDaemon is running...)
Cause
No IP address is found for the device server listed.
Resolution
- Check cflist.cgi and .rhttps files if IP is present.
- If not, modify infraDB and save the changes.
- Delete .rhttps and restart the service, file will restart upon successful restart of vcmaster.