VoyenceControl: Automatic pulls are not scheduled for Juniper devices when traps are forwarded through an intermediary server
book
Article ID: 303501
calendar_today
Updated On:
Products
VMware
Issue/Introduction
Symptoms:
Automatic pulls are not scheduled for Juniper devices when traps are forwarded through an intermediary server
Environment
VMware Smart Assurance - NCM
Cause
Voyence is unable to locate the device IP in the trap because there is no agent-addr value in the trap header. Juniper devices do not include the agent-addr in the trap by default and it will only be sent with SNMPv1 traps.
Resolution
The device must be configured to send SNMPv1 traps and to include the agent-addr:
Configure your trap-group to send SNMP v1 or all (both v1 and v2c) trap types:
set snmp trap-group <groupname> version (v1"all)
Configure your trap-options to send the agent-addr:
set snmp trap-options agent-addr outgoing-interface
Commit your changes. Now traps will contain the agent-addr. Voyence will use this to lookup the device and schedule automatic pulls.