将 vCenter Server 5.5 迁移到 vCenter Server Appliance 6.0 U2m 失败
search cancel

将 vCenter Server 5.5 迁移到 vCenter Server Appliance 6.0 U2m 失败

book

Article ID: 301332

calendar_today

Updated On:

Products

VMware vCenter Server

Issue/Introduction

Symptoms:
免责声明:本文为 Migrating vCenter Server 5.5 to vCenter Server Appliance 6.0 U2m fails (2147746) 的翻译版本。尽管我们会不断努力为本文提供最佳翻译版本,但本地化的内容可能会过时。有关最新内容,请参见英文版本。


 
  • 预检查过程中运行 Migration Assistant 失败
  • 在 %temp%\migration-assistant.log 文件中,您会看到类似以下内容的条目:

    |migration-assistant-4191364| I: ParseErrorsWarningsFromPreUpgradeOutput: Parsed 1 error messages. |migration-assistant-4191364| I: ParseErrorsWarningsFromPreUpgradeOutput: Error messages: Error: Internal error occurs during VMware vCenter Server Database pre-upgrade checks.
     
  • 扩展:
Virtual Storage Console(NetApp, Inc. 发行): https://vCenter-Server-System-Name:8143/vSphereExtensionDescriptor.xml
Virtual Storage Console(NetApp, Inc. 发行): https://vCenter-Server-System-Name:8143/webclient_deployment_bundle
注意:NetApp MSI 插件本地安装在 Windows vCenter Server 5.5 上。

Environment

VMware vCenter Server Appliance 6.0.x
VMware vCenter Server 5.5.x

Cause

MSI 插件安装在源 Windows vCenter Server 上,导致 Migration Assistant 预检查失败时,会出现此问题。

Resolution

要解决此问题,请卸载 vCenter 上的 Netapp 插件/MSI。

迁移到 VCSA 6.0U2 后,请在任何 Windows 计算机上安装 MSI 插件并在安装过程中将其与 VCSA 集成。插件应在 vSphere Web Client 中可见。