Performance Monitor Extract job PMSMFEX, receives IEC130I SYS030 DD STMT Missing/SYS040 at IDMS release 18.0 and higher.
search cancel

Performance Monitor Extract job PMSMFEX, receives IEC130I SYS030 DD STMT Missing/SYS040 at IDMS release 18.0 and higher.

book

Article ID: 30099

calendar_today

Updated On:

Products

IDMS IDMS - Database IDMS - ADS

Issue/Introduction

SYS030/SYS040 DD Statements referenced by the Performance Monitor PMSMFEX extract were introduced at IDMS release 18.0 for Type 230 SMF records (SYS030) and SMF Type 4 records (SYS040).

At IDMS releases prior to r18.0, these records went to SYS020. Incidentally, if you left out a SYS020 DD statement in 17.0 and prior releases, you would get the IEC130I for SYS020.

Information on the new SYS030/SYS040 DD statements for PMSMFEX for 18.0 are in the CA IDMS Performance Monitor System Administration Guide, in the section titled:

Using SMF to Archive Statistics (z/OS only)

 

If not extracting SMF 230 or 4 records, then DD DUMMY on those statements can be used.

By the way, even if PMSMFEX is really not writing SMF type 4 or 30 records, it will attempt to open those DDNAMEs.

 

The DD Statements for SYS030 and SYS040 are as follows:

//SYS030 DD DSN=user.pmsmfex.outsmf30,DISP=(NEW,CATLG,DELETE),

// UNIT=disk,SPACE=(CYL,(5,2)),

// DCB=(RECFM=VB,LRECL=698,BLKSIZE=23038)

//SYS040 DD DSN=user.pmsmfex.outsmf4,DISP=(NEW,CATLG,DELETE),

// UNIT=disk,SPACE=(CYL,(5,2)),

// DCB=(RECFM=VB,LRECL=259,BLKSIZE=23055) 

Environment

Release: IDADSO00100-18.5-ADS-for CA-IDMS
Component: