When I execute the CA InterTest Batch r 9.1 CLIST I receive IEC141I 013-18 pointing to INT1PARM.
search cancel

When I execute the CA InterTest Batch r 9.1 CLIST I receive IEC141I 013-18 pointing to INT1PARM.

book

Article ID: 29830

calendar_today

Updated On:

Products

InterTest - CICS InterTest - Batch

Issue/Introduction

When executing any of the following CA InterTest Batch 9.1 CLIST 'S (MR91CLST, MR91CDBS, MR91CIMS and MR91CBTS) the user receives error message IEC141I 013-18  pointing to the INT1PARM DD statement. 

IEC141I 013-18,IGG0191B,USER-ID,CATSO,INT1PARM,532A,TSU028,

HLQ.IB91.CAMRSRC

IEA995I

 SYMPTOM DUMP OUTPUT

SYSTEM COMPLETION CODE=013  REASON CODE=00000018

  TIME=17.19.55  SEQ=03092  CPU=0000  ASID=01C1

  PSW AT TIME OF ERROR  075C1000   80E282EE  ILC 2  INTC 0D

    NO ACTIVE MODULE FOUND

    NAME=UNKNOWN

    DATA AT PSW  00E282E8 - 4100302C  0A0D010D  A7E5014B

    AR/GR 0: 007F8B58/00000000_00E285F8   1: 00000000/00000000_A4013000

          2: FFFFFFFF/FFFFFFFF_000B2088   3: FFFFFFFF/FFFFFFFF_00E285CC

          4: FFFFFFFF/FFFFFFFF_00799410   5: FFFFFFFF/FFFFFFFF_007997A4

          6: FFFFFFFF/FFFFFFFF_0079974C   7: FFFFFFFF/FFFFFFFF_007997A4

          8: FFFFFFFF/00000000_0079976C   9: FFFFFFFF/FFFFFFFF_00000080

          A: FFFFFFFF/FFFFFFFF_0079B310   B: FFFFFFFF/FFFFFFFF_00798D94

          C: FFFFFFFF/FFFFFFFF_00000008   D: FFFFFFFF/00000000_00000000

          E: 00000000/00000000_80E27B4C   F: 00000000/00000000_00000018

  END OF SYMPTOM DUMP

Abend 013000 hex occurred processing command 'CALL    '.

*** 

This error is caused by currently allocating the INT1PARM DD to the CAMRSRC dataset as follows:

ALLOC  DD(INT1PARM)  DSN('&PREFIX.CAMRSRC')       SHR

To correct the IEC141I error please point to the CAMRSAMP dataset as outlined below.

ALLOC  DD(INT1PARM)  DSN('&PREFIX.CAMRSAMP')       SHR

Environment

Release:
Component: INTBAT