BOSH Director UAA fails with "unbound variable" error when installing Ops Manager
search cancel

BOSH Director UAA fails with "unbound variable" error when installing Ops Manager

book

Article ID: 293681

calendar_today

Updated On:

Products

Operations Manager

Issue/Introduction

The BOSH Director failing to run when installing Operations Manager (Ops Manager).
Waiting for instance 'bosh/0' to be running... Failed

Running monit summary on the BOSH Director shows that there is an issue with UAA.
Process 'uaa' Execution failed

Checking the uaa.stderr.log on the BOSH Director shows the reason for the failure:
/var/vcap/jobs/uaa/bin/configure_proxy: line 13: proxy_conf[1]: unbound variable


Environment

Product Version: 2.7

Resolution

This issue is due to an unbound variable in the startup script for UAA.

A fix has been released and is included in Ops Manager release 2.7.3. For more information, refer to the following documentation: https://docs.pivotal.io/platform/2-7/release-notes/opsmanager-rn.html#2-7-3