This article discusses useful commands on a DCA v1 with respect to the omreport utility.
Always use omhelp omreport commands to show help manual of omreport.
1. System Component Properties
System logs:
omreport system alertlog --View alert log. omreport system esmlog --View hardware (Embedded System Management) log. omreport system cmdlog --View command log.
OS:
[root@sdw1 ~]# omreport system operatingsystem Operating System Information Host Name : sdw1 Operating System : Red Hat Enterprise Linux Server Operating System Version : release 5.5 (Tikanga) Kernel 2.6.18-194.11.1.el5 (x86_64) System Time : Mon Nov 12 13:46:39 2012 System Bootup Time : Wed Mar 16 10:22:25 2011
Summary of all system components(Including major components versions):
[root@sdw1 ~]# omreport system summary System Summary ------------------ Software Profile ------------------ Systems Management Name : Server Administrator Version : 6.3.0 Description : Systems Management Software Contains : A library for parsing GNU style command line arguments 6.3.0 : Data Engine 5.9.3 : Hardware Abstraction Programming Interface 5.9.3 : Instrumentation Services 5.9.3 : Modular Server Virtual Media CLI Utils 1.0.0 : Monolithic Server Virtual Media CLI Utils 1.0.0 : OpenManage Inventory Collector 6.3.0 : RAC Command Interface 4.6.5 : RAC Integration Layer 6.3.0 : Remote Access Card Data Populator 6.3.0 : Server Administrator Common Framework 6.3.0 : Server Administrator Core and CLI 6.3.0 : Server Administrator XML Support SDK 6.3.0 : Storage Management System Utilities Package / Libsysfs 1.3.0 : Storage Management accessors package 3.3.0 : Storage Management common files for GUI and CLI 3.3.0 : Storage Management populator package 3.3.0 : StoreLib package for storage management 6.3.0 : System Utilities Package/Libsysfs for LSI storage libraries 2.1.0 : iDRAC Command Interface 6.3.0 Operating System Name : Red Hat Enterprise Linux Server Version : release 5.5 (Tikanga) Kernel 2.6.18-194.11.1.el5 (x86_64) System Time : Mon Nov 12 13:48:46 2012 System Bootup Time : Wed Mar 16 10:22:25 2011 (......)
Version report for all components that enable updating. (Including BIOS, OS and controller versions)
[root@sdw1 ~]# omreport system version Version Report --------------------- Main System Chassis --------------------- Name : BIOS Version : 1.3.6 Name : iDRAC6 Version : 1.52 ---------- Software ---------- Name : Red Hat Enterprise Linux Server Version : release 5.5 (Tikanga) Kernel 2.6.18-194.11.1.el5 (x86_64) Name : Dell Server Administrator Version : 6.3.0 ----------------------------- Storage Controller Firmware ----------------------------- Name : PERC H700 Integrated Version : 12.3.0-0032
2. Chassis Component Properties
Check power peak stats and threshold:
[root@sdw1 ~]# omreport chassis pwrmonitoring Power Consumption Information Power Consumption Index : 2 Status : Ok Probe Name : System Board System Level Reading : 308 W Warning Threshold : 917 W Failure Threshold : 966 W Amperage Location : PS 1 Current Reading : 0.6 A Location : PS 2 Current Reading : 0.6 A Power Headroom Attribute : System Instantaneous Headroom Value : 663 W Attribute : System Peak Headroom Value : 452 W Power Tracking Statistics Statistic : Energy Consumption Measurement Start Time : Wed Aug 11 10:22:01 2010 Measurement Finish Time : Mon Nov 12 14:02:38 2012 Reading : 467.2 KWh Statistic : System Peak Power Measurement Start Time : Tue Jul 27 19:21:16 2010 Peak Time : Mon Aug 6 09:58:23 2012 Peak Reading : 520 W Statistic : System Peak Amperage Measurement Start Time : Tue Jul 27 19:21:16 2010 Peak Time : Tue Jul 27 19:34:17 2010 Peak Reading : 4.2 A
Check power capacity:
[root@sdw1 ~]# omreport chassis pwrmanagement Power Inventory and Budget Power Inventory Attribute : System Idle Power Value : 383 W Attribute : System Maximum Potential Power Value : 715 W Power Budget Attribute : Enable Power Cap Values : Disabled Attribute : Power Cap Values : 715 W ( 100% )
Power health status:
[root@sdw1 ~]# omreport chassis pwrsupplies Power Supplies Information --------------------------------------- Main System Chassis Power Supplies : Ok --------------------------------------- Power Supply Redundancy : Ok Attribute : Redundancy Status Value : Full Individual Power Supply Elements Index : 0 Status : Ok Location : PS 1 Status Type : AC Rated Input Wattage : 972 W Maximum Output Wattage : 750 W Online Status : Presence Detected Power Monitoring Capable : Yes Index : 1 Status : Ok Location : PS 2 Status Type : AC Rated Input Wattage : 972 W Maximum Output Wattage : 750 W Online Status : Presence Detected Power Monitoring Capable : Yes
Fans:
[root@sdw1 ~]# omreport chassis fans|grep -i stat Attribute : Redundancy Status Status : Ok Status : Ok Status : Ok Status : Ok Status : Ok Status : Ok Status : Ok Status : Ok Status : Ok Status : Ok Memory [root@sdw1 ~]# omreport chassis memory|egrep "Index|Status" Index : 0 Status : Ok Index : 1 Status : Ok Index : 2 Status : Ok Index : Status : Unknown Index : 3 Status : Ok Index : 4 Status : Ok Index : 5 Status : Ok Index : Status : Unknown
NICs:
[root@sdw1 ~]# omreport chassis nics|egrep "Name|Status" Interface Name : eth0 Connection Status : Connected Interface Name : eth1 Connection Status : Disabled Interface Name : eth2 Connection Status : Connected Interface Name : eth3 Connection Status : Connected CPUs [root@sdw1 ~]# omreport chassis processors Processors Information Health : Ok Index : 0 Status : Ok Connector Name : CPU1 Processor Brand : Intel(R) Xeon(R) CPU X5670 @ 2.93GHz Processor Version : Model 44 Stepping 2 Current Speed : 2933 MHz State : Present Core Count : 6 Index : 1 Status : Ok Connector Name : CPU2 Processor Brand : Intel(R) Xeon(R) CPU X5670 @ 2.93GHz Processor Version : Model 44 Stepping 2 Current Speed : 2933 MHz State : Present Core Count : 6
Temperatures:
[root@sdw1 ~]# omreport chassis temps Temperature Probes Information ------------------------------------ Main System Chassis Temperatures: Ok ------------------------------------ Index : 0 Status : Ok Probe Name : System Board Ambient Temp Reading : 27.0 C Minimum Warning Threshold : 8.0 C Maximum Warning Threshold : 45.0 C Minimum Failure Threshold : 3.0 C Maximum Failure Threshold : 50.0 C Voltage [root@sdw1 ~]# omreport chassis volts|egrep "Index|Status" Index : 0 Status : Ok Index : 1 Status : Ok Index : 2 Status : Ok Index : 3 Status : Ok Index : 4 Status : Ok Index : 5 Status : Ok Index : 6 Status : Ok Index : 7 Status : Ok Index : 8 Status : Ok Index : 9 Status : Ok Index : 10 Status : Ok Index : 11 Status : Ok Index : 12 Status : Ok Index : 13 Status : Ok Index : 14 Status : Ok Index : 15 Status : Ok Index : 16 Status : Ok Index : 17 Status : Ok Index : 18 Status : Ok Index : 19 Status : Ok Index : 20 Status : Ok
Battery of CMOS:
[root@sdw1 ~]# omreport chassis batteries Batteries Health : Ok Individual Battery Elements Index : 0 Status : Ok Probe Name : System Board CMOS Battery Reading : Good
3. Display Storage Component Properties
Physical Disk Status:
[root@sdw1 ~]# omreport storage pdisk controller=0|egrep "^ID |Status|State|Failure" ID : 0:0:0 Status : Ok Power Status : Spun Up State : Online Failure Predicted : No ID : 0:0:1 Status : Ok Power Status : Spun Up State : Online Failure Predicted : No (......)
Logical Disk Status:
[root@sdw1 ~]# omreport storage vdisk|egrep "^Name|State|Write|Read" Name : root State : Ready Read Policy : Adaptive Read Ahead Write Policy : Write Back Name : data State : Ready Read Policy : Adaptive Read Ahead Write Policy : Write Back Name : root State : Ready Read Policy : Adaptive Read Ahead Write Policy : Write Back Name : data State : Ready Read Policy : Adaptive Read Ahead Write Policy : Write Back
Controller Status:
[root@sdw1 ~]# omreport storage controller|egrep "^ID|^State|^Status|^Firmware" ID : 0 Status : Ok State : Ready Firmware Version : 12.3.0-0032 Controller Battery [root@sdw1 ~]# omreport storage battery List of Batteries in the System Controller PERC H700 Integrated (Slot 4) ID : 0 Status : Ok Name : Battery 0 State : Ready Recharge Count : Not Applicable Max Recharge Count : Not Applicable Predicted Capacity Status : Ready Learn State : Idle Next Learn Time : 37 days 20 hours Maximum Learn Delay : 7 days 0 hours Learn Mode : Auto
Controller Connecter Status:
[root@sdw1 ~]# omreport storage connector controller=0|egrep "^ID|Status" ID : 0 Status : Ok ID : 1 Status : Ok Tips: On segments, please make sure that, each vdisk contains 6 pdisks, otherwize the vdisk may be in degraded status even if all pdisks are healthy. [root@sdw1 ~]# omreport storage pdisk controller=0 vdisk=1|grep ^ID ID : 0:0:0 ID : 0:0:1 ID : 0:0:2 ID : 0:0:3 ID : 0:0:4 ID : 0:0:5 [root@sdw1 ~]# omreport storage pdisk controller=0 vdisk=2|grep ^ID ID : 0:0:6 ID : 0:0:7 ID : 0:0:8 ID : 0:0:9 ID : 0:0:10 ID : 0:0:11
4. Battery Issue Related
Generate system log:
[root@sdw1 ~]# omconfig storage controller action=exportlog controller=0 Command successful!
Check Manufacture Name:
[root@sdw1 ~]# logfile=`ls -t /var/log/lsi*.log|head -1`;cat $logfile | grep 'Manufacturer Name' | head -n 1; omreport chassis info | grep 'Chassis Service Tag' T5: Manufacturer Name : SMP-PA1.9 Chassis Service Tag : 1VCCJN1 Check remaining&full capacity [root@sdw1 ~]# logfile=`ls -t /var/log/lsi*.log|head -1`;cat $logfile | grep -A 8 'BATTERY MONITORED INFORMATION' |tail -8| cut -c 6- ____________________________________________________________________________ Temperature : 28 C Voltage : 4066 V Current : 0 mA GasGaugeStat : 40e0 GPID : 81110d2 ChargerStatus : 2 Remaining Capacity : 1612 mAh Full Charge Capacity: 1625 mAh Relative Stat of Charge : 100 % FwBBUState : 1 ____________________________________________________________________________