App Control: Carbon Black App Control Reporter Service Start Failure: 'Error 1053: The service did not respond to the start'
search cancel

App Control: Carbon Black App Control Reporter Service Start Failure: 'Error 1053: The service did not respond to the start'

book

Article ID: 290304

calendar_today

Updated On:

Products

Carbon Black App Control (formerly Cb Protection)

Issue/Introduction

  • Not able to start the Carbon Black App Control Reporter service, following message reported:
Windows could not start the Carbon Black App Control Reporter service on Local Computer.
Error 1053:The service did not respond to the start or control request in a timely fashion.
  • Manually starting the Carbon Black App Control Reporter service reports following message: 
Cannot start Carbon Black App Control Reporter due to not enough space on the disk.

 

Environment

  • App Control Server: All Versions
  • App Control Reporter service: All Versions

Cause

Disk drive ran out of space.

Resolution

  • Add more space to disk drive, and/or remove extraneous files from disk drive.

Additional Information

  • To start Carbon Black App Control Reporter service manually
  1. Open command prompt with elevated privilege (right mouse -> Run as Administrator)
  2. Run following command: 
C:\Program Files (x86)\Bit9\Parity Server\Reporter>ParityReporter.exe start