App Control: TenAsys INtime COM Port Assignment Failure
search cancel

App Control: TenAsys INtime COM Port Assignment Failure

book

Article ID: 289885

calendar_today

Updated On:

Products

Carbon Black App Control (formerly Cb Protection)

Issue/Introduction

When starting a machine running INtime the Console returns the error: COM_ISM::SetRtInterruptHandler Returned 5 for level 58.

Environment

App Control Agent: All Supported Versions

Cause

This is caused by a slight delay the agent adds during the startup sequence. 
 

Resolution

The following value should be added to the affected endpoints registry:
  1. Create HKLM:\software\tenasys\intime\rtkernelloader if it doesn't already exist
  2. Then add the following as a DWORD entry: ACPITimeout = 60000

Additional Information

Please remember to perform a backup of the registry prior to testing any changes.