CB Response: How to Properly Terminate a Live Response Session
search cancel

CB Response: How to Properly Terminate a Live Response Session

book

Article ID: 289857

calendar_today

Updated On:

Products

Carbon Black EDR (formerly Cb Response)

Issue/Introduction

To properly terminate a Live Response session and avoid unnecessary timeouts.

Environment

  • CB Response Server: All versions

Resolution

While actively connected to a Live Response session:
  1. To detach from a session but leave it active:
# detach
  1. To fully end a session with the sensor:
# session close

 

Additional Information

  • Sessions will timeout when they are not attached and active for five minutes.
  • Restarting the cb-liveresponse service will terminate all active sessions.
  • Each session has a unique numeric ID.
  • Up to 10 sessions can be running at one time, and multiple users can be attached to the same session.