mon_config_service (MCS) probe fails to start after upgrade to DX UIM 23.4
search cancel

mon_config_service (MCS) probe fails to start after upgrade to DX UIM 23.4

book

Article ID: 282480

calendar_today

Updated On:

Products

DX Unified Infrastructure Management (Nimsoft / UIM)

Issue/Introduction

After the upgrade to DX UIM 23.4 the mon_config_service (MCS) probe fails to start.

Looking at the probe log the following is observed:

 

Apr 16 19:05:17:493 [Thread-5734, mon_config_service] SelfServiceNimProbe.shutdown:30:    Java heap space
java.lang.OutOfMemoryError: Java heap space

Apr 16 19:05:14:246 [PollerGroupMaintenanceController-5981, mon_config_service] PollerGroupMaintenanceController.managePollerGroups:55:    Starting timed pollergroup management
Apr 16 19:05:44:971 [Thread-5744, mon_config_service] TimeController.notifyProfileChanges:234:    Start Notify Profile Changes
Apr 16 19:05:44:971 [PollerGroupMaintenanceController-5971, mon_config_service] SelfServiceNimProbe.shutdown:30:    Java heap space
java.lang.OutOfMemoryError: Java heap space

Apr 16 19:05:44:975 [PollerGroupMaintenanceController-5971, mon_config_service] SelfServiceNimProbe.shutdown:32:    Fatal error, shutting down for therapeutic restart!!!

 

Environment

DX UIM 23.4.*

 

Cause

CFG corruption. missing section. 

Resolution

Verify the integrity of the mon_config_service.cfg. it might be missing sections, in particular missing the Java startup info. 

1) Deactivate the probe and then redeploy the same version of the probe on top of the existing one

2) Increase the out-of-the-box memory allocation or restore the previous setting to ensure enough memory is allocated.