BMP and DL/1 Batch is not monitored with IMSICEPT and IMSSSA is YES
search cancel

BMP and DL/1 Batch is not monitored with IMSICEPT and IMSSSA is YES

book

Article ID: 282479

calendar_today

Updated On:

Products

Mainframe Application Tuner

Issue/Introduction

Are there any other settings/definitions to monitor BMP and IMS Batch ? MATUNE does not monitor IMS job with following definitions.

HLQ.UTRPARM(TUNSSP00)
IMSICEPT=YES
IMSSSA=YES

Specify target name: (Job required)                                          
  Job ===> jobname  Step ===>          Pstep ===>          Prog ===>        
   Multi-Step Monitoring ===> YES  (YES or NO)                                 
Specify parameters for target job name:   
Monitor entire step ===> YES    (Yes or No)        

 

Environment

Release 12.0

Resolution

If MATUNE does not monitor BMP or IMS Batch job with "Multi-Step Monitoring=>YES", try to set  "Multi-Step Monitoring=>NO" and specify "Job", "Step", "Pstep".

HLQ.UTRPARM(TUNSSP00)
IMSICEPT=YES
IMSSSA=YES
Specify target name: (Job required)                                            
  Job ===> jobname  Step ===> stepname  Pstep ===> pstepname   Prog ===>        
   Multi-Step Monitoring ===> NO  (YES or NO)                                 
Specify parameters for target job name:   
Monitor entire step ===> NO    (Yes or No)