RECEIVE of PTF LU09889 fails with NOT RECEIVED PTF NO APPLICABLE ++VER
search cancel

RECEIVE of PTF LU09889 fails with NOT RECEIVED PTF NO APPLICABLE ++VER

book

Article ID: 282166

calendar_today

Updated On:

Products

Optimizer/II

Issue/Introduction

SMP/E RECEIVE of Optimizer/II release 8.5 PTF LU09889 fails with the following message:  

LU09889  NOT RECEIVED  PTF     NO APPLICABLE ++VER

Environment

Z/OS 

Cause

Fix LU09889 is for FMID COX8500. FMID COX8500​ is an optional FMID and is not applied in the Optimizer/II SMP/E environment. 

Resolution

Optimizer/II has two types of licenses. The COMPILE TIME license and the RUNTIME License. The COX8500 FMID only ships with the COMPILE TIME license.

FMID COX8500​ is an optional FMID and is NOT required.
 
If the COX8500 FMID is not applied in the SMP/E environment, then fix LU09889 is not required.  

Every Optimizer/II PTF contains a ++VER that identifies the owning FMID of the element specified in the PTF, along with additional information regarding prerequisites and/or superseding fixes.  
The message:  LU09889 NOT RECEIVED  PTF NO APPLICABLE ++VER
produced during SMP/E RECEIVE processing means that the FMID specified in the ++VER statement within the PTF is not installed - applied in the SMP/E environment. 
 
Below is the ++VER statement associated with fix LU09889. 

++PTF (LU09889) REWORK(2023111)
++VER (Z038)                      
  FMID (COX8500)                  
  PRE ( RO57287 RO57599 RO61643 )
  SUP ( LT09889 RO34120 TR34120 )