Trying to Receive the Endevor maintenance using a Receive Order job and it is failing with the following errors:
IEC032I E37-04,IFG0554P,NDVRCVOR,RECEIVE,SMPPTS,235A,VOLSER, 518
iprfx.iqual.ENDEVOR.V190.SMPPTS
IEC032I E37-04,IFG0554P,NDVRCVOR,RECEIVE,SMPPTS,235A,VOLSER, 523
iprfx.iqual.ENDEVOR.V190.SMPPTS
IEC032I E37-04,IFG0554P,NDVRCVOR,RECEIVE,SMPPTS1,AC9F,VOLSER, 526
iprfx.iqual.ENDEVOR.V190.SMPPTS1
IEC032I E37-04,IFG0554P,NDVRCVOR,RECEIVE,SMPPTS1,AC9F,VOLSER, 528
iprfx.iqual.ENDEVOR.V190.SMPPTS1
All supported versions
The SMPPTS and SMPPTS1 need to be reallocated larger.
1) Rename the existing SMPPTS and SMPPTS1 datasets with a .OLD suffix
2) Allocate a new SMPPTS dataset as a PDSE with a 1000 cylinders primary and 500 cylinders secondary:
Organization . . . : PO
Record format . . . : FB
Record length . . . : 80
Block size . . . . : 27920
1st extent cylinders: 1000
Secondary cylinders : 500
Data set name type : LIBRARY
3) Allocate a new SMPPTS1 dataset as a PDSE with 500 cylinders primary and 500 cylinders secondary:
Organization . . . : PO
Record format . . . : FB
Record length . . . : 80
Block size . . . . : 27920
1st extent cylinders: 500
Secondary cylinders : 500
Data set name type : LIBRARY
//SMPWRK1 DD UNIT=SYSDA,SPACE=(CYL,(80,25,15)),DCB=BLKSIZE=3120
//SMPWRK2 DD UNIT=SYSDA,SPACE=(CYL,(80,25,15)),DCB=BLKSIZE=3120
//SMPWRK3 DD UNIT=SYSDA,SPACE=(CYL,(80,25,15)),DCB=BLKSIZE=3120
//SMPWRK4 DD UNIT=SYSDA,SPACE=(CYL,(80,25,15)),DCB=BLKSIZE=3120
//SMPWRK5 DD UNIT=SYSDA,SPACE=(CYL,(80,25,15)),DCB=BLKSIZE=3120
//SMPWRK6 DD UNIT=SYSDA,SPACE=(CYL,(80,25,15)),DCB=BLKSIZE=3120
7) After the Receive and Apply have successfully completed, delete the .OLD SMPPTS and SMPPTS1 datasets.