VMWARE probe: Collection time is longer than poll time
book
Article ID: 281583
calendar_today
Updated On:
Products
DX Unified Infrastructure Management (Nimsoft / UIM)
Issue/Introduction
vmware probe does not collect all monitors and generates a 'Polling interval was less than the collection time' alarm
Error captured in the vmware.log
Caused by: java.io.EOFException
at java.util.zip.GZIPInputStream.readUByte(GZIPInputStream.java:268)
at java.util.zip.GZIPInputStream.readUShort(GZIPInputStream.java:258)
at java.util.zip.GZIPInputStream.readHeader(GZIPInputStream.java:164)
at java.util.zip.GZIPInputStream.<init>(GZIPInputStream.java:79)
Cause
Error indicates that the template is suspect (corrupted)
Resolution
1. Delete the vmware probe from IM or Admin Console
2. Delete the vmware probe folder
3. Redeploy the vmware probe
4. Add the vmware probe source and recreated the template