After an IPL CEMMON is not coming up.
search cancel

After an IPL CEMMON is not coming up.

book

Article ID: 281530

calendar_today

Updated On:

Products

Compliance Event Manager

Issue/Introduction

CEMMON receives the following errors starting after an IPL.

                                                               
ACF01004 LOGONID XXXXX NOT FOUND                                                                        
CEM0644E CEM Change Monitor SQL ERROR SQLCODE: FFFFFDD9 SQLERRM: DBA0308.EXECUTE PACKAGE.ECACMDB2.ECACMDB2
IEA794I SVC DUMP HAS CAPTURED:  490                                                                       
DUMPID=003 REQUESTED BY JOB (CEMMON  )                                                                    
CEM0640E CEM Change Monitor error has occurred - terminating                           

Environment

z/os

Cause

Logonid is using a User ID that nolonger exists

Resolution

Rebind of package

PACKAGE.ECACMDB2.ECACMDB2

with a valid user id