Issue/Introduction
Model shows Critical red in the Alarms tab but green in the Explorer tab in OneClick.
Environment
Version: Any Component: OneClick
Cause
Information in the OneClick cache
OneClick caches a lot of information and sometimes this cached information can cause issues like not displaying the correct condition. Especially if the SpectroSERVER has to be restarted or a database reloaded.
Resolution
Flush the OneClick cache.
Log out of OneClick
Shutdown tomcat and webtomcat. Ensure they are not running.
Remove the $SPECROOT/tomcat/work and $SPECROOT/webtomcat/work directories. These are the cache directories. They will be recreated when tomcat and webtomcat are restarted.