We are experiencing communication issues while attempting to open the controller probe.
This problem has arisen since we started using the new cluster and CDM build version 7.11-T3 and 7.11-T1.
Previously, everything was working fine, but now both the controller and CDM probes are not opening and showing communication errors.
Cluster 7.11-T3
CDM version 7.11-T1
Modification in the new build.
Resolve this issue by removing "audit = 6" from the robot.cfg file on all servers where the problem was occurring. Then, restart the Nimsoft watcher service for the changes to take effect.