BGHC001E CA SYSVIEW for DB2 data collector error
search cancel

BGHC001E CA SYSVIEW for DB2 data collector error

book

Article ID: 280968

calendar_today

Updated On:

Products

SYSVIEW Performance Management Option for DB2 for z/OS

Issue/Introduction

What conditions specifically might cause this alert to happen?
"DBGHC001E CA SYSVIEW for DB2 data collector XXXXXXX dispatching priority may result in lost trace data"      

 

Environment

z/os

Cause

Dispatching Priority Levels

Resolution

The message is issued by the Healthchecker when the Datacollector dispatching priority is lower than the DB2 Address spaces.

See 

DBGHC001E

Ensure the Datacollector has a dispatching priority equal or greater than the DB2 address spaces.

Note you can check the current dispatching priority of the various address spaces 
e.g Datacollector and DB2 Address spaces 

by using the "DISPLAY MVS" command from the Sysview for DB2 Menu command line and over typing the job name with the