DB2 PTF UI93345 (APAR PH55622), included in IBM's Recommended
Service Upgrade (RSU) RSU2309, adds nine additional Instrumentation
sections to the SMF type 100-0 DB2 Statistics record, resulting in a total
of 24 Instrumentation sections.
When data at this RSU level is processed by MICS in a
DAY065 or INCR065 step:
- The 15 expected sections are processed normally
- The 9 new sections are ignored
- MICSLOG message DB200004E is written to MICSLOG for
each SMF type 100-0 record containing 24 Instrumentation
sections:
DB200004E !!!!! UNANTICIPATED SECTION COUNT !!!!!
DB200004E SYSTEM RECORD - INSTRUMENTATION SECTION 24
DB200004E !!!!! UNANTICIPATED SECTION COUNT
The statistics contained in the nine additional SMF type 100-0
Instrumentation sections are not available for analysis in the MICS
DB2DSY DB2 System Activity file.
Code updates are required to process the nine additional instrumentation
sections added by IBM's RSU2401.
MICS Analyzer Option for DB2 r14.4
DB26943 - Prevent DB200004E MICSLOG Messages and Enhancements