File system alerts are auto closing every one minute
search cancel

File system alerts are auto closing every one minute

book

Article ID: 280477

calendar_today

Updated On:

Products

DX Unified Infrastructure Management (Nimsoft / UIM)

Issue/Introduction

The setup that is made in the CDM probe is not being saved, once the probe GUI is closed, all configured settings are removed.

File system alerts are closed every minute and state that "Profile Deleted/Modified. Clear old alarms"

 

 

 

Environment

Release: DX UIM 20.4.CU5

Component: Cluster probe: 3.27

                     CDM probe: 7.20

Cause

Defect.

There was a corruption happening due to CDM and cluster updating the CDM cfg.

In the new attached fixes, the controller will update the CDM. cfg on behalf of CDM and Cluster as shown in the below diagram:

Resolution

To deploy the attached builds (cdm-7.20-T1.zip and cluster-3.72-T3.zip) on the problematic server, follow the steps given below:

Deployment Steps:


1. Remove the old CDM and cluster probe.
2. Remove the cdm and cluster folder from the backend servers.
3. Deploy the latest cluster build.
4. Deploy the cdm probe.

 

Attachments

cluster-3.72-T3.zip get_app
cdm-7.20-T1-20240216.101241-15.zip get_app