When adding elements to Endevor, the error C1LB040E occurs and forces the ELIB to go into a READ-ONLY status. This error only occurs against specific systems with the same ELIB Delta file.
C1LB040E ELIB INTERNAL LIFETIME LIMIT EXCEEDED. CONTACT YOUR ADMIN.
C1G0000I DATA SET ENDEVOR.ELIB.DELTA
C1G0000I MEMBER XXZRSP8P
SMGR154E I/O ERROR WRITING FILE - DDN=SYS00022
C1G0277I ADD PROCESSING TERMINATED BECAUSE OF THE PREVIOUS ERROR
C1G0200I ELEMENT ACTION REQUEST PROCESSING COMPLETED, HIGHEST ENDEVOR RC WAS 0012
C1G0236E PROCESSING TERMINATED - ENDEVOR RC 12 IS GREATER THAN OR EQUAL TO STOP RETURN CODE 12
All support Releases
This problem will occur only if one of the following PTFs are installed:
These PTF's introduce messages C1LB039I and C1LB040E:
The following HIPER PTFS have been published to resolve the problem:
If there is a need to verify if an ELIB needs immediate attention , the following steps can be followed:
To verify if an ELIB data set needs immediate action, perform the Inquire function of the BC1PNLIB utility:
//STEP1 EXEC PGM=BC1PNLIB
//STEPLIB DD DISP=SHR,DSN=YOUR.ENDEVOR.CSIQAUTH
// DD DISP=SHR,DSN=YOUR.ENDEVOR.CSIQLOAD
//SYSPRINT DD SYSOUT=*
//SYMDUMP DD SYSOUT=*
//SYSUDUMP DD SYSOUT=*
//BSTERR DD SYSOUT=*
//ELIB1 DD DISP=SHR,DSN=YOUR.ELIB
//SYSIN DD *
INQUIRE DDNAME=ELIB1 .
*** IMPORTANT NOTE - The REORG function of the BC1PNLIB utility DOES NOT resolve the problem. ***