CA1 abended with S0C4 after Date Simulate upgraded to V3.0
search cancel

CA1 abended with S0C4 after Date Simulate upgraded to V3.0

book

Article ID: 279062

calendar_today

Updated On:

Products

Date Simulator

Issue/Introduction

CA1 abended S0C4 after Date Simulate upgraded to V3.0
CA1 getting the following eror
SYSTEM COMPLETION CODE=0C4  REASON CODE=00000011

Cause

Date Simulator rel 3.0 was using SVC 233 the old version was using 235, and CA1 was using svc 233.

Resolution

You must supply Date Simulator with the number of an unused type 3 SVC in the range of 200-255.