I have added the audit probe to my primary hub and added the setup/auditing section and key to enable auditing on the wasp probe, based on the 2 articles below
https://techdocs.broadcom.com/us/en/ca-enterprise-software/it-operations-management/unified-infrastructure-management/23-4/administering/UIM-Auditing-in-APIs.html
https://knowledge.broadcom.com/external/article/128820/enable-monitoring-for-configuration-chan.html
But I noticed that the "wasp_audit_details" and "AUDIT_CONFIG_CHANGES" SQL database tables are not populated. May I know what are the events that will write to this table
UIM 23.4
1) wasp_audit_details are updated when you do create, delete or update UIM configuration performed using UIM Operator console or its related APIs are recorded as per auditing.
The example UIM configurations are Inventory, Groups, Discovery Scopes, and so on. I deleted devices from inventory and wasp_audit_details and wasp_audit_log were populated.
2) AUDIT_CONFIG_CHANGES are updated when you edit config from Infrastructure Manager.
For this to work, please make sure audit needs is enabled enabled on the robot