DataCollector gets an IEC161I 052(013,ZZZIDB2)-084 at Startup
search cancel

DataCollector gets an IEC161I 052(013,ZZZIDB2)-084 at Startup

book

Article ID: 278629

calendar_today

Updated On:

Products

SYSVIEW Performance Management Option for DB2 for z/OS

Issue/Introduction

After maintenance to Sysview for DB2 the DataCollector abends with a message

IEC161I 052(013,ZZZIDB2)-084,ZZZINDC,ZZZINDC,HSTSTATS,,,  719       
IEC161I XXXX.HSTSTATS,XXXX.HSTSTATS.DATA, 
IEC161I CATALOG.XXXX  

 
at startup.

Environment

z/os

Cause

Statistic Datasets were being shared across Datacollectors

Resolution

From the DataCollector job log this error message is seen

IEC161I 052(013,ZZZIDB2)-084,ZZZINDC,ZZZINDC,HSTSTATS,,,  719       
IEC161I XXXX.HSTSTATS,XXXX.HSTSTATS.DATA, 
IEC161I CATALOG.XXXX  

The 052(013,ZZZIDB2)-084 code signifies the dataset mentioned in the message
is already opened somewhere else.


These datasets should be specific for each Datacollector and not shared.

HSTSTATS-DSN='XXXX.HSTSTATS'  
HSTACCTG-DSN='XXXX.HSTACCTG'        

Create new Datasets for 
HSTSTATS-DSN  
HSTACCTG-DSN