Event Monitor 21.x for z/OS triggers Automatic File Event as DASD-extent is created and not only in case of normal close operation
search cancel

Event Monitor 21.x for z/OS triggers Automatic File Event as DASD-extent is created and not only in case of normal close operation

book

Article ID: 277699

calendar_today

Updated On:

Products

CA Automic Workload Automation - Automation Engine

Issue/Introduction

After upgrading the Agent MVS from 12.x to 21.x, it is observed that the Event monitor with V21 does File-Triggering (SMF Type 15) for every DASD-Extent and not only one time for the completed (closed) data set, whereas it should only do it in case of normal close operation as it used to do on previous versions.

Environment

Component: Agent MVS Version 21.x

Sub-Component: Event Monitor

Cause

Defect on Agent MVS 21.x

Resolution

Update to a fix version listed below or a newer version if available.

Fix version:
Component(s): Agent MVS
Will be fixed in Automation.Engine 21.0.10 - Planned release end April 2024

Additional Information

Bug ID: AE-34887

Public Description: A problem has been solved where Automatic File Event for z/OS is triggered as DASD-extent was created and not only in case of normal close operation.