we can see only inventory is synced in OI, none of the alarms are being published to OI.
from the log:-
2023-12-29 03:09:33,360 ERROR [HttpResponseHandler] [handleIOException] - Connection IOException: https://apmservices-gateway.oilab.local/jarvis/v2/ingestion/
2023-12-29 03:09:37,553 WARN [AbstractHttpErrorHandler] [retryHttpErrorRequest] - Retrying ALARM sync for https://apmservices-gateway.oilab.local/jarvis/v2/ingestion/ with HTTP error code : 400
2023-12-29 03:09:37,553 ERROR [HttpResponseHandler] [handleIOException] - Connection IOException: https://apmservices-gateway.oilab.local/jarvis/v2/ingestion/
2023-12-29 03:09:37,553 WARN [JarvisHttpErrorHandler] [stopAllSyncs] - Stopping all Jarvis syncs ALARM
DX OI 23.1
Spectrum 23.3.1
Change the jarvis ingestion point in the OIConfig.xml file back to v1. Then alarms work.