IMS task is abending with 0C4 after applying maintenance to IMS
CAPTURED DUMPS=0001, SPACE USED=00004185M, SPACE FREE=00010815M
DUMPID=006 TITLE=title ABEND SYS 0C4 USER 0000-010,
DATE.TIME: date.time, CALLER=CTL , TCB=CTL,
MODULE=UNKNOWN ,P
DUMP TAKEN TIME=hh.mm.ss DATE=mm/dd/yyyy
ERRORID=SEQ09611 CPU0000 ASIDxxxx TIME=hh.mm.ss
SYSTEM ABEND CODE=0C4 REASON CODE=00000010
MODULE=TSSI150 CSECT=*UNKNOWN
PSW AT TIME OF ERROR=47741000 80000000 00000000 00350820
ILC=4 INT=10
TRANSLATION EXCEPTION ADDR=00000000_72F0F400
ABENDING PROGRAM ADDR=******** RECOVERY ROUTINE=********
AR/GR 0-1 00000001/00000000_27719A30 00000000/00000000_27719718
AR/GR 2-3 00000000/00000000_00000000 00000000/00000000_00BEE048
AR/GR 4-5 00000000/00000000_27719758 00000000/00000000_277197A0
AR/GR 6-7 00000000/00000000_2771974D 00000000/00000000_3FE8F1B0
AR/GR 8-9 00000000/00000000_27719718 00000000/00000000_3FE8F070
AR/GR10-11 00000000/00000000_3A2D55B4 00000000/00000000_00B4B890
AR/GR12-13 00000000/00000000_00350730 00000000/00000000_F2F0F0F0
AR/GR14-15 00000000/00000000_800DC610 44000000/00000000_002B5000
IEA995I SYMPTOM DUMP OUTPUT
Z/OS 2.4
IMS 15.4
IBM RSU2306 or greater + IBM maintenance PH49469
If the system is at IBM RSU2306 or greater, the application of IBM maintenance PH49469 causes 0C4 abends to occur in the IMS region.
Multiple 0C4 abends occur in the IMS region. The IMS region eventually becomes inactive.