Abend S0C4 in IMS after applying PH49469
search cancel

Abend S0C4 in IMS after applying PH49469

book

Article ID: 276747

calendar_today

Updated On:

Products

Top Secret

Issue/Introduction

IMS task is abending with 0C4 after applying maintenance to IMS

CAPTURED DUMPS=0001, SPACE USED=00004185M, SPACE FREE=00010815M
     DUMPID=006 TITLE=title  ABEND SYS 0C4 USER 0000-010,
                      DATE.TIME: date.time, CALLER=CTL , TCB=CTL,
                      MODULE=UNKNOWN ,P
         DUMP TAKEN TIME=hh.mm.ss DATE=mm/dd/yyyy
         ERRORID=SEQ09611 CPU0000 ASIDxxxx TIME=hh.mm.ss
         SYSTEM ABEND CODE=0C4  REASON CODE=00000010
         MODULE=TSSI150  CSECT=*UNKNOWN
         PSW AT TIME OF ERROR=47741000 80000000 00000000 00350820
         ILC=4 INT=10
         TRANSLATION EXCEPTION ADDR=00000000_72F0F400
         ABENDING PROGRAM ADDR=******** RECOVERY ROUTINE=********
     AR/GR 0-1  00000001/00000000_27719A30  00000000/00000000_27719718
     AR/GR 2-3  00000000/00000000_00000000  00000000/00000000_00BEE048
     AR/GR 4-5  00000000/00000000_27719758  00000000/00000000_277197A0
     AR/GR 6-7  00000000/00000000_2771974D  00000000/00000000_3FE8F1B0
     AR/GR 8-9  00000000/00000000_27719718  00000000/00000000_3FE8F070
     AR/GR10-11 00000000/00000000_3A2D55B4  00000000/00000000_00B4B890
     AR/GR12-13 00000000/00000000_00350730  00000000/00000000_F2F0F0F0
     AR/GR14-15 00000000/00000000_800DC610  44000000/00000000_002B5000
IEA995I SYMPTOM DUMP OUTPUT 

                

Environment

Z/OS 2.4

IMS 15.4 

IBM RSU2306 or greater + IBM maintenance PH49469

 

Cause

If the system is at IBM RSU2306 or greater, the application of IBM maintenance PH49469 causes 0C4 abends to occur in the IMS region.          

Multiple 0C4 abends occur in the IMS region. The IMS region eventually becomes inactive.                                                                              

Resolution

Open a case to request the test fix LT11836.

Check first if the published version is available (LU11836)