Spooler Probe in Error State and Not Starting (DX UIM / Nimsoft)
search cancel

Spooler Probe in Error State and Not Starting (DX UIM / Nimsoft)

book

Article ID: 276203

calendar_today

Updated On:

Products

DX Unified Infrastructure Management (Nimsoft / UIM)

Issue/Introduction

This KB addresses scenarios where the UIM spooler probe turns red and fails to start due to port exhaustion.

The controller.log shows the below:

Nov 17 09:53:57:005 [] 0 spooler: sockServer: requested port 48001 is already in use (for host=)

Nov 17 09:53:57:005 [] 0 spooler: nimSession - failed to create server session on port 48001, error code 22

Nov 17 09:53:57:005 [] 0 spooler: nimCreateServer session failed.

Nov 17 09:53:58:005 [] Controller: Max. restarts reached for probe 'spooler' (command = spooler)

Environment

CA DX Unified Infrastructure Management (Nimsoft / UIM): all supported versions

Cause

Port 48001 (default spooler listening port) is actively occupied by another competing application or process on the host.

Resolution

 

Identify the Conflicting Process

  • Windows: Open Command Prompt as Administrator and run:

    netstat -ano | findstr :48001
    

    Note the PID (process ID) in the rightmost column, then find the process using tasklist | findstr <PID> or Task Manager.

  • Linux / Unix: Run:

    netstat -tulnp | grep 48001
    # or
    ss -tulnp | grep 48001

Clear Orphaned Nimsoft Processes

  • Stop the Nimsoft Robot Watcher service (Nimsoft Robot Watcher on Windows or niminit stop on Linux).

  • Ensure all related processes (e.g., controller, spooler, hdb) have stopped completely. Kill any lingering process manually if needed.

  • Restart the Nimsoft service.

Option A: Free Up Port 48001

  • If another application is using port 48001, stop or reconfigure that third-party service so UIM can claim its default port.

Option B: Reconfigure UIM to Use Different Ports

 

If the robot is accessible from IM:

  • Open Raw Configure: From Infrastructure Manager (IM), right-click the target robot's controller probe and select Raw Configure.

 

  • Select Controller Section: Ensure the main controller section is highlighted in the configuration tree.

  • Add Custom Port Key: Click New Key and define a new port mapping to bypass the conflict:

    • Key Name: spooler_port

    • Key Value: 48004 (or any available port within the 48000s range)

  • Apply and Restart: Click Apply and OK. The robot will automatically restart the probe hierarchy.

  • Verify Status: Confirm in IM that the spooler probe turns green and successfully binds to the new port and PID.

 

 

If the robot is not accessible from IM:

  • Edit the robot.cfg file located in the Nimsoft installation folder:

     
    controller_port = 48005
    spooler_port = 48001
    first_probe_port = 48004
    