When using sample JCL in HLQ.CAVHJCL member CAVHCONF to change the global options, the link edit step fails with the following errors:
IEW2677S 5130 A VALID ENTRY POINT COULD NOT BE DETERMINED.
IEW2230S 0414 MODULE HAS NO TEXT.
IEW2677S 5130 A VALID ENTRY POINT COULD NOT BE DETERMINED.
IEW2012I 0F09 ALL TEMPNAMES HAVE BEEN USED. THE MODULE CANNOT BE SAVED.
IEW2008I 0F03 PROCESSING COMPLETED. RETURN CODE = 12.
Z/OS
The assembly default options were set to NOOBJECT as shown below.
Options for this Assembly
NOOBJECT
Add the OBJECT option to the Assembly step ASM as shown below.
//ASM EXEC PGM=ASMA90,REGION=2M,
// PARM='LIST,XREF(SHORT),RENT,
This will create an object deck to be processed by the linkage editor.