How to address the Consistency Check error below.
ERROR : ICCBR14E UNFORMATTED input (CLEAR SCREEN INPUT) is defined for a non-screened Procedure Step.
Release : 8.6
To resolve the ICCBR14E UNFORMATTED input message, please review the following steps.
1. In the Dialog Design, highlight the Procedure and click Detail, Step Properties. It is set to 'no display'. Close this out, it is just for info.
2. With the same Procedure highlighted, click Detail , 'Clear screen input'. Delete 'your' attribute from the 'Clear screen with user input' section. NOTE: Since the Procedure is set to 'no display', you will never have the option for a user to start it with 'user input'.
Once 'your' attribute is removed from the 'Clear screen with user input' section, the CC Error will no longer occur. Please give it a try and let me know your results.